DATA Cable     CAT 7+ Multimedia

Electrical Charateristics at 20° Celsius              
Frequency in MHz 1 10 16 20 31,25 62,5 100 300 600 1000 1200
                       
Dämpfung in dB / 100 meters according Norm* 2,1 6,0 7,6 8,5 10,6 15,0 19,0 33 50 -- --
Typical Values dB / 100 meters 1,7 4,7 6,2 6,9 8,8 12,5 16,0 28 40 50 55
Nahnebensprechdämpfung in dB according Norm* 80 80 80 80 80 75,3 71,1 63,7 60    
Typical Values dB / (Bzl. 100 meters) 96 96 96 96 96 95 94 86 80 75 70
ACR in dB (=Reserve for System) 94 91 90 89 87 83 78 58 40 25 15
                       
  Norm: demand for an installed 100 meter cable of CATEGORY 7 Distance F, prEN50288-4-1  
 
Größter Schleifenwiderstand 118 W / kilometer
Größter Widerstandsunterschied 3%
Isolationswiderstand > 5000 MW x km
Impedanz Zo at 0,064 MHz 125 W ± 20 %
Impedanz Zo at 1.......100 MHz 100 W ± 15 %
Kopplungsnwiderstand 2 W / kilometer at 10 MHz
Rückflußdämpfung at 100 meters: 1..... 100 MHz > 23 dB
Rückflußdämpfung at 100 meters: 100..... 300MHz  16 dB 
Erdungssymetrie dB / BZL = 1000 meters > 46 dB bei 64 kHz
Erdungssymetrie dB / BZL = 100 meters > 40 dB bei 1 MHz
Betriebskapazität 42 pF / m
Größte Entkopplung bei 0.001 MHz 1000 pF / kilometer
Ausbreitungsgeschwindigkeit 0,8 x c / 80 % 
Signallaufzeit 4,5 ns / meter                                                   
 
 
Mechanical Charateristics                        
Aderisolierung Foam-skin-PE-Isolation
Mantelmaterial free of halogen, not inflamable material, RAL 2003 = orange
Einsatzort dry and humid room, tubes etc. locations
Temperaturbereich ( at moving) 0........+50° Celsius
Temperaturbereich (at fixed temperature) -20°........+60° Celsius
min. Biegeradius für einmalies Biegen ³ 45 mm (for 2x (4x2...) over flat side of cable)
Biegeradius whilst process of installation ³ 65 mm (for 2x (4x2...) over flat side of cable)
Durchmesser des Kupferleiters 0,64 mm
 

 

19.08.2002