| Electrical
Charateristics at 20° Celsius |
|
|
|
|
|
| Frequency in MHz |
1 |
10 |
16 |
20 |
31,25 |
62,5 |
100 |
300 |
|
| |
|
|
|
|
|
|
|
|
|
| Dämpfung in dB / 100 meters
according Norm* |
2,1 |
6,6 |
8,2 |
9,2 |
11,8 |
17,1 |
22 |
-- |
|
| Typical Values dB / 100 meters |
1,9 |
5,6 |
7,0 |
7,8 |
9.8 |
13,9 |
17,7 |
32.2 |
|
| Nahnebensprechdämpfung in dB
according Norm* |
62 |
47 |
44 |
42 |
40 |
35 |
32 |
|
|
| Typical Values dB / (Bzl. 100 meters) |
77 |
62 |
59 |
57 |
54 |
50 |
46 |
39 |
|
| ACR in dB (=Reserve for System) |
75 |
56 |
52 |
49 |
44 |
36 |
28 |
7 |
|
| |
|
|
|
|
|
|
|
|
|
| |
DIN EN 50173 and ISO / TEC
11801, demand for an installed 100 meter cable of CATEGORY
5
Distance D |
|
| |
| Größter Schleifenwiderstand |
185 W
/ kilometer |
| Größter Widerstandsunterschied |
3% |
| Isolationswiderstand |
> 5000 MW
x km
|
| Impedanz Zo at 0,064 MHz |
125 W
± 20 % |
| Impedanz Zo at 1.......100 MHz |
100 W
± 15 % |
| Kopplungsnwiderstand |
> 10 mW
/ at 10 MHz |
| Rückflußdämpfung at 100 meters:
1..... £ 20 MHz |
> 23 dB |
| Rückflußdämpfung at 100 meters:
1..... < 20 MHz |
23 dB - 10
log ( f / 20 ) |
| Erdungssymetrie dB / BZL = 1000
meters |
> 46 dB bei 64 kHz |
| Betriebskapazität |
48 pF / m |
| Größte Entkopplung bei 0.001 MHz |
1600 pF / kilometer |
| Ausbreitungsgeschwindigkeit |
0,74 c / 74 % |
| Signallaufzeit |
4,5 ns / meter |
| |
 |
| |
| Mechanical
Charateristics |
| Aderisolierunt |
Foam-skin-PE-Isolation |
| Mantelmaterial |
free of halogen, not
inflamable material, RAL 6018 = green |
| Einsatzort |
dry and humid room
locations |
| max. Temperaturbereich at time of
installation |
0........+50° Celsius |
| max. Betriebstemperatur |
-20°........+60°
Celsius |
| min. Biegeradius für einmaliges
Biegen |
³ 35mm
(for 2x ( 4x3....) über flache Seite) |
min. Biegeradius während der
Verlegung bzw.
Einziehen |
³ 50mm
(for 2x ( 4x3....) über flache Seite) |
| Durchmesser des Kupferleiters |
0,51 mm |
| |