Electrical
Charateristics at 20° Celsius |
|
|
|
|
|
|
Frequency in MHz |
1 |
10 |
16 |
20 |
31,25 |
62,5 |
100 |
200 |
300 |
600 |
|
|
|
|
|
|
|
|
|
|
|
Dämpfung in dB / 100 meters
according Norm* |
2,1 |
6,0 |
7,6 |
8,5 |
10,7 |
15,5 |
19,9 |
29,9 |
-- |
-- |
Typical Values dB / 100 meters |
1,9 |
5,6 |
7,2 |
8,0 |
10,2 |
14,5 |
18,5 |
27 |
33 |
48 |
Nahnebensprechdämpfung in dB
according Norm* |
66 |
65,3 |
56,2 |
54,8 |
51,9 |
47,4 |
44,3 |
39,8 |
-- |
-- |
Typical Values dB / (Bzl. 100 meters) |
96 |
96 |
96 |
96 |
96 |
95 |
94 |
90 |
86 |
80 |
ACR in dB (=Reserve for System) |
94 |
90 |
89 |
88 |
86 |
81 |
76 |
63 |
53 |
32 |
|
|
|
|
|
|
|
|
|
|
|
|
prEN50288-5-1 1st
June 99, demand for an installed 100 meter cable of CATEGORY
6 Distance
E |
|
|
Größter Schleifenwiderstand |
164 W
/ kilometer |
Größter Widerstandsunterschied |
3% |
Isolationswiderstand |
> 5000 MW
x km
|
Impedanz Zo at 0,064 MHz |
125 W
± 20 % |
Impedanz Zo at 1.......100 MHz |
100 W
± 15 % |
Kopplungsnwiderstand |
> 10 mW
/ at 10 MHz |
Rückflußdämpfung at 100 meters:
1..... 100 MHz |
> 23 dB |
Rückflußdämpfung at 100 meters:
100..... 300MHz |
16 dB |
Erdungssymetrie dB / BZL = 1000
meters |
> 46 dB bei 64 kHz |
Erdungssymetrie dB / BZL = 100
meters |
> 40 dB bei 1 MHz |
Betriebskapazität |
43 pF / m |
Größte Entkopplung bei 0.001 MHz |
1000 pF / kilometer |
Ausbreitungsgeschwindigkeit |
0,79 c / 79 % |
Signallaufzeit |
4,5 ns / meter |
|
 |
|
Mechanical
Charateristics |
Aderisolierunt |
Foam-skin-PE-Isolation |
Mantelmaterial |
free of halogen, not
inflamable material, RAL 6018 = green |
Einsatzort |
dry and humid room,
tubes etc. locations |
Temperaturbereich ( at moving) |
0........+50° Celsius |
Temperaturbereich (at fixed
temperature) |
-20°........+60°
Celsius |
min. Biegeradius |
5 x Diameter (at
duplex cable over the flat side) |
Biegeradius whilst process of
installation |
7,5 x Diameter ( at
duplex cables over the flat side |
Durchmesser des Kupferleiters |
0,55 mm |
|